Control your Autoterm diesel heater precisely with the Comfort Control panel. Several operating modes are available.
REF: AT0050
Comfort Control Panel:
Product Description:
The Comfort Control panel is designed to offer you intuitive and efficient management of your Autoterm diesel heater , whether for the AIR series forced-air heaters or the FLOW series water heaters. This device allows you to pre-program the start and stop of your heater, ensuring optimal thermal comfort on board your Motorhome, Campervan, or boat.
Main Features:
-
Intuitive Interface : Easy handling thanks to a simplified user interface.
-
LED Status Display : View at a glance information related to your heater's operation.
-
Enhanced Thermostat : Regulate the temperature with increased precision thanks to an integrated digital sensor.
-
Additional Heating Options : Access customized heating modes for a tailored experience.
-
Timer Function : Program your heater for a specific duration, for example 3 hours, to suit your needs.
-
Battery Safety Function : Protect your vehicle's battery with a system that limits energy consumption.
-
Monthly Maintenance Reminder : A built-in reminder informs you of the necessary maintenance to ensure the longevity of your heater.
-
Eco Mode for Water Heaters : Enjoy energy savings while maintaining a comfortable temperature.
Technical Features:
-
Available Languages : FR / EN / NL
-
Quick Access to Settings : Adjust parameters, timer, and heating modes even during operation.
-
Automatic Ventilation Stop : Once the temperature is reached, the ventilation stops completely for absolute silence.
-
Protective film included : Protect your control panel from scratches and wear.
Usage tips:
To properly disconnect your control panel, it is important to disconnect the pin/clip at the end of the wire. Never pull directly on the wire as this may damage the internal soldering, which is not covered by the warranty. Any incorrect handling will void repair coverage.
| Modes - forced air heaters |
TEMPERATURE MODE: The heater will maintain the set temperature by reducing heating power.
POWER MODE : The heater will operate constantly at the set power level.
HEATING TEMPERATURE + VENTILATION: The heater will operate until the temperature reaches 1°C above the set temperature, stops the combustion process and starts ventilating until the temperature drops 5°C below the set temperature. When the temperature drops, the heater restarts.
THERMOSTAT MODE: The heater will operate until the specified temperature is reached, then stops the combustion process and ventilation. Once the temperature has dropped by the specified degrees, the heater will restart.
|
| Modes - water heaters |
PREHEATING MODE: The heater will operate until the coolant temperature is reached, then stops the combustion process. Once the coolant temperature drops, the heater restarts.
ECO MODE: (only for FLOW 14D) Preheating mode with reduced power and fuel consumption. The coolant temperature is reached more slowly than in "preheating mode".
THERMOSTAT MODE* : (only for FLOW 5D/B) The heater will operate until the specified indoor temperature is reached, then stops the combustion process. Once the temperature has dropped by the specified degrees, the heater will restart. The temperature is read by the control panel. * to configure the "thermostat mode", see the instructions for AIR heaters.
|
| Temperature sensor |
Custom calibrated digital sensor with an offset of +/- 1.5 degrees.
|
| Timers |
Max - 3 timers. The heating mode can be selected for each timer.
All 3 timers can be active simultaneously. The setting timer remains active continuously until it is deactivated
Available cycles:
- ED - Every day
- EW - Every workday
- Custom days
|
| Status display |
- Display
- Red LED - heating
- Blue LED - ventilation
- Green LED - off
|
| Screen dimensions |
37 x 20 mm |
| Control panel dimensions |
82 x 37 x 19 mm
|
Compatibility:
This control panel is suitable for the following heaters:
Air heaters
- Autoterm Air 2D
- Autoterm Air 4D
- Autoterm Air 8D
- Autoterm Air 9D
Water heaters
- Autoterm Flow 5D/5B
- Autoterm Flow 14D
Control cables:
- REF: 2067 - Wiring for control panel (1.8 m)
- REF: 2324 - Wiring for control panel (5.0 m)
- REF: 3298 - Wiring for control panel (7.0 m)
- REF: 4269 - Wiring extension for control panel (2.6 m)
- REF: 4366 - Wiring harness for AUTOTERM Flow 5D (12V)
- REF: 4044 - Wiring harness for AUTOTERM Flow 5D / 5B (12V)
- REF: 4394 - AUTOTERM Flow 14D wiring harness for control panel (1.8 m)
Maximum allowed wiring length with Comfort Control - 10 m
Control panel position: The PU 27 and Comfort control have a built-in temperature sensor. Care must be taken with its placement during installation: do not place it next to an air vent or too far from the heating area, behind curtains, in direct sunlight, near the ceiling, or too close to the floor.